Resumen
This paper presents a two-control loop design considering the nonlinear time-varying characteristics of a single-phase grid-connected photovoltaic (PV) full-bridge central inverter. The control scheme design is based on the energy-balance modeling of the PV system and enables the design of a voltage loop linear discrete controller ensuring the stability of the system for the whole range of PV array operating conditions. A set of experimental results carried out on a laboratory prototype is provided to validate the proposed approach.
| Idioma original | Inglés |
|---|---|
| Páginas (desde-hasta) | 2734-2743 |
| Número de páginas | 10 |
| Publicación | IEEE Transactions on Industrial Electronics |
| Volumen | 55 |
| N.º | 7 |
| DOI | |
| Estado | Publicada - jul 2008 |
| Publicado de forma externa | Sí |