Abstract
Titanium-based lattice structures have gained significant attention in biomedical engineering due to their potential to mimic bone-like behavior and improve implant performance. This study evaluates the performance of bio-inspired Ti64 TPMS Gyroyd and Stochastic lattice structures fabricated via Powder Bed Fusion-Laser Beam (PBF-LB), focusing on their in-vivo and ex-vivo mechanical and biological responses for biomedical applications. Utilizing an SLM 280 HL printer, samples exhibited notable geometric accuracy essential for mechanical integrity. The study highlights significant mechanical properties and geometric precision improvements achieved through chemical etching. Mechanical characterization revealed that the as-built Gyroid lattice had the highest elastic modulus (3.64 GPa) and yield strength (200.65 MPa), which improved post-etching (3.62 GPa and 219.35 MPa, respectively). The Stochastic lattice demonstrated lower yield strength values post-etching (169.81 MPa). In-vivo analyses in horse models, both structures demonstrated excellent biocompatibility and osseointegration with no adverse inflammatory responses. Ex-vivo push-out tests showed that the chemically etched Gyroid structure achieved the highest resistance to push-out force (1645.407 N) and most significant displacement (2.754 mm), indicating superior energy absorption (4920.425 mJ). These findings underscore the critical influence of microstructural design and surface treatments on implant functionality, offering novel insights into improving biomedical implant performance through lattice architecture and post-processing.
| Original language | English |
|---|---|
| Article number | 101450 |
| Journal | Materials Today Bio |
| Volume | 31 |
| DOIs | |
| State | Published - Apr 2025 |
Keywords
- Bio-inspired materials
- Biocompatibility
- Biomedical implants
- Mechanical properties
- Osseointegration
- Powder bed fusion-laser beam (PBF-LB)
- Ti64 lattice structures
Fingerprint
Dive into the research topics of 'In-vivo and ex-vivo evaluation of bio-inspired structures fabricated via PBF-LB for biomedical applications'. Together they form a unique fingerprint.Projects
- 1 Active
-
Estudio del comportamiento biomecánico-osteointegración de implantes biomédicos procesados con tecnologías de manufactura avanzada
Araya Calvo, M. (Institutional academic collaborator), Cubero Sesin, J. (Institutional academic collaborator), Ureña Sandí, N. (Institutional academic collaborator), Guillén Girón, T. (Institutional academic coordinator), Estrada, R. (External collaborating researcher ), Vindas Bolaños, R. (External collaborating researcher ), Järvenpää, A. (Institutional academic coordinator), Rautio, T. (Institutional academic coordinator), Kawamura, Y. (External collaborating researcher ), Horita, Z. (External collaborating researcher ) & Corrales-Brenes, R. (Institutional academic coordinator)
1/01/24 → 31/12/26
Project: Research Projects Internally funded › Technological Development
Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver