Abstract
This paper explores the electrical performance of a recessed probe launch (RPL) technique for measurement of embedded (internal) printed circuit board (PCB) structures such as striplines and vias (plated through holes). The RPL uses high-frequency microprobes in combination with a milling technique that removes upper board layers and exposes internal probing points. A two-tier calibration technique is applied for the extraction of the S-parameters of the RPLs with the help of thru-reflect-line calibration standards designed on PCB. Full-wave models are used to corroborate and validate the obtained S-parameters. Good model-to-hardware correlation is obtained up to 40 GHz. Furthermore, the launch performance with respect to microprobe positioning and variations of the cavity size is investigated using the full-wave models. These simulations suggest techniques for launch optimization and probe modifications that improve the launch measurement bandwidth.
| Original language | English |
|---|---|
| Article number | 6291781 |
| Pages (from-to) | 3198-3206 |
| Number of pages | 9 |
| Journal | IEEE Transactions on Instrumentation and Measurement |
| Volume | 61 |
| Issue number | 12 |
| DOIs | |
| State | Published - 2012 |
| Externally published | Yes |
Keywords
- De-embedding
- multilayer printed circuit board (PCB)
- thru-reflect-line (TRL) calibration
- two-tier calibration
- vector network analyzer
Fingerprint
Dive into the research topics of 'Electrical performance of the recessed probe launch technique for measurement of embedded multilayer structures'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver