This paper explores the electrical performance of a recessed probe launch (RPL) technique for measurement of embedded (internal) printed circuit board (PCB) structures such as striplines and vias (plated through holes). The RPL uses high-frequency microprobes in combination with a milling technique that removes upper board layers and exposes internal probing points. A two-tier calibration technique is applied for the extraction of the S-parameters of the RPLs with the help of thru-reflect-line calibration standards designed on PCB. Full-wave models are used to corroborate and validate the obtained S-parameters. Good model-to-hardware correlation is obtained up to 40 GHz. Furthermore, the launch performance with respect to microprobe positioning and variations of the cavity size is investigated using the full-wave models. These simulations suggest techniques for launch optimization and probe modifications that improve the launch measurement bandwidth.

Original languageEnglish
Article number6291781
Pages (from-to)3198-3206
Number of pages9
JournalIEEE Transactions on Instrumentation and Measurement
Volume61
Issue number12
DOIs
StatePublished - 2012
Externally publishedYes

Keywords

  • De-embedding
  • multilayer printed circuit board (PCB)
  • thru-reflect-line (TRL) calibration
  • two-tier calibration
  • vector network analyzer